Need some help redesigning grow room

So I’m a bit out date and have been wanting to get some Gavitas but have been struggling to figure out how I should go about changing anything.. the entire room is 15’ X 13’ with a 8’ ceiling and the space I’m currently using in it is roughly 8’ X 11’ which are tables that I split into two 3.5’ X 11’ rows on short flood drain tables with scrog tables. I currently have been running 6 air cooled hoods 3 per row. I’m also in 3 gal pots on the flood drain table at the moment to note for later-
I was thinking of ripping the tables out that I have now and re doing it with three tables that would be 3 and a half feet wide by 8 feet long with a foot and a half In between each table to able to get in and work with them. Or doing one table against the wall that is 3 and a half feet wide and 8 foot long and then doing a second table 7 foot wide and 8 foot long with a foot and half to work with on both sides of the table.
Or option three dropping the pots to the ground with saucer and making scrog nets to accomedate the same space size.
Any ideas or constructive criticism is greatly appreciated!
 

BigHornBuds

Well-Known Member
I would (do)run a de1000 with a 4x4
I would probably have 8-9 4x4 tables in the middle on wheels , when I need to work, push them apart ,

I run 10g pots on the floor , 4 under a light .
 
I would (do)run a de1000 with a 4x4
I would probably have 8-9 4x4 tables in the middle on wheels , when I need to work, push them apart ,

I run 10g pots on the floor , 4 under a light .
Only problem is I’m limited on ac and have 14k btu to play with, I barely squeak by with the 6 hoods at the moment and was hoping I could use less hoods
 

Renfro

Well-Known Member
Much appreciated! How’s the heat load off the 1000s? Would I be able to handle three of them with 14k btus for ac?
Probably if you don't have any other heat load. Personally I math DE 1kW lights at 4500 BTU/hr per light.
 
You’d be pushing that ac to the max , if your
Running a burner they kick out lots of heat too.
No burner running bottles, only other heat load is the dehu but I’m in the desert so it isn’t used to frequent. I know it’s pushing it but I’m trying to make due until I can upgrade!
 

Renfro

Well-Known Member
No burner running bottles, only other heat load is the dehu but I’m in the desert so it isn’t used to frequent. I know it’s pushing it but I’m trying to make due until I can upgrade!
If the AC can't handle it, just run the lights dimmed until you can get more AC in place.
 