Drivers and LED F series/H inFlux strips - best choices ??

Randomblame

Well-Known Member
Hey do you guys think 3x H_inFlux L09's gonna be enough in my 2x2 tent? I'm planning to run them with ELG-150-42A. Which gives me the option to use same driver for new oncoming https://www.samsung.com/led/lighting/led-modules/industrial-light-module/horticulture-linear/# So I can just switch 3x L09's with 3 of these on same frame and driver if I decide to. Is this a good idea? I can also add the 4th strip later on and run them more efficent if I wanted to.(almost 0.9amps at max)
150/165w is enough for a 2x 2' area. But L09 has 44,6v which means you should use an ELG-150-48. ELG-series needs also 220-240vac, with 110v you only get ~70% driver output.

Edit!
Would also work with the new horti strips..
 
Last edited:

GentleCaveman

Well-Known Member
150/165w is enough for a 2x 2' area. But L09 has 44,6v which means you should use an ELG-150-48. ELG-series needs also 220-240vac, with 110v you only get ~70% driver output.

Edit!
Would also work with the new horti strips..
ELG-150-42 dims between 37.8 ~ 46.2V

I live in europe, so we are getting 220-240vac.

edit: new horti strips has 43.1 operating voltage @1200mamps ELG-150-48 dims between 43.2 ~ 52.8V
 