Lots of Questions....exhaust 3 600 lamps

gwerns nugs

Well-Known Member
SO here we go.

I have a 7'6" wall and a 6'6" wall that are against a corner (cement) of a garage. I have the walls framed and up. I am in the stages of getting the door on and hinges mounted. So heres the tricky part. I want to fit 3 600w HPS lamps in there...the room is

7'6" Long by 6'6" Wide

I dont have any experience rigging fans and exhausting....lol my last two grows were pretty ghetto but it was the learning that i needed. NOW i have funds available and want to do it right. CAN SOMEONE PLZ HELP me troubleshoot setting up my exhaust in and out with 3 600 ( IDEALLY) I guess i can settle to do 2 :).

THANKS in advance!
 

scoregreen

Well-Known Member
i get a chub when i look at this setup

i have a similar thread -- but he deals with something more your size. if you stack three of what he has youd be in good shape -- if you werent going hydro/aeroponics, just use the vent/light part of his grow room.

good luck!
 

DubsFan

Well-Known Member
i get a chub when i look at this setup

i have a similar thread -- but he deals with something more your size. if you stack three of what he has youd be in good shape -- if you werent going hydro/aeroponics, just use the vent/light part of his grow room.

good luck!
Hey can you hook up a better link for the "setup." That one didn't work.
 

gwerns nugs

Well-Known Member
link didnt work!@ REALLY WANA SEE IM GETTING MY ROOM WIRED TOMORROW PICKING UP MONEY FROM THE BANK and headed to grow store to drop a G stak
 

billybob88

Well-Known Member
check out my previous grow, the billybob scrog. i had 2 600s vented. heres how i had it rigged. carbon filter inside room-duct-1st light-duct-2nd light-duct-can fan-duct into attic. I have a big enough can fan to pull air from the room through the lights as my vent system and then an a/c duct running into the room cooling it. worked pretty good. vented lights is the only way to go.
 

gwerns nugs

Well-Known Member
So heres my room, it is 7 feet 6" long by 6'7" wide. I need to vent out the front because the other 3 walls two being concrete and one being my roomates future grow op. That leaves me to vent out the front wall by the door. I want to run 2 lamps in veg and 3 in flower. I already had my electrician friend come out and he said I am all good....just need some input on how and where to cut these holes for my 6" exhause holes. PS i have a 8" S&P fan plus another 440 cfm inline fan with an air scrubber.........can I PLEASE PLEASE PLEASE GET SOME INPUT
 

Attachments

M Blaze

Well-Known Member
Just exhaust at the top and intake from the bottom. I usually run 4 x 600s and all I use is a big carbon filter to exhaust and a vent down below on the other side of the room for fresh air intake.
 

brucetree

Active Member
SO here we go.

I have a 7'6" wall and a 6'6" wall that are against a corner (cement) of a garage. I have the walls framed and up. I am in the stages of getting the door on and hinges mounted. So heres the tricky part. I want to fit 3 600w HPS lamps in there...the room is

7'6" Long by 6'6" Wide

I dont have any experience rigging fans and exhausting....lol my last two grows were pretty ghetto but it was the learning that i needed. NOW i have funds available and want to do it right. CAN SOMEONE PLZ HELP me troubleshoot setting up my exhaust in and out with 3 600 ( IDEALLY) I guess i can settle to do 2 :).

THANKS in advance!
see this.

https://www.rollitup.org/marijuana-pics/images/1698/large/1_ventilation.gif
 

gwerns nugs

Well-Known Member
I dont wana fuck with the roof. It is water proof and i wana keep it that way....I can ONLY vnt outa the wall with the door on it. ONCE AGAIN. THANKS GUYS BUT I CAN ONLY VENT FROM THE WALL WITH THE DOOR ON IT. I DO NOT WANA FUCK WITH THE CEILING....any more inout would be great
So I drill an 8" hole to accomodate my 8" SP fan BLOW air IN the room THROUGH the lights hook up my other 440cfm inline fan AFTER OR IN THE MIDDLE OF the 2nd /3rd light and where does my carbon filter go? At the end of the lights......another dillemma running c02 dont wana vent out my c02 every time i gotta fix temps.....im using a sentinel CHHC-1...sick shit input?
 

gwerns nugs

Well-Known Member
so can someone gimme some help....I THINK i need two more fans....BUT i am not sure this is how i see it running correct me if im wrong

PS i am venting upward then out on my AIR OUT......there is a 7" drywall gap between the true ceiling....i am gonna cut a hole and run the tubing out....

FOR my light venting i was gonna cut a hole in my existing wall. I have holes for wiring to escape along with my irrigation system. Can i get some help on how many more fans i need....or if i need to bust out an ac?
 

Attachments