Veg Rm Specs:
- 3' W x 5.5' D x 3.5'-7' H. (under a staircase)
- 4 bulb 4' T8/32w fixture, 2 cool white, 2 warm white. Hang from chains.
- 2- 2 bulb 4' T12/40w fixtures each with one cool white and one warm white. Mounted on the wall behind plants.
- one 12"or so, table top fan, should be oscilating but it was a hand me down and just clicks.
Room has remained at high 70s with about 55-60% hum, since construction @ the end of Oct.
There is no active ventalation and I believe that I should be fine given the small size of the room.
Flower Rm. Specs:
- 2.5' W x 5.5' D x 7' H
- 400w/ HPS/ 6" CoolTube.
- One med tower fan
- 4" inline bilge/galley fan-240 cfm.(It's for boats and only cost me $35.00 off Ebay with shipping)
- Current set up is missing the inline fan because it has not arrived yet. Based on the "heat rises" concept the cold air intake for the CoolTube is aprx. 18" off of the floor while the hot air exhaust runs to a 6"-4" reducer fitting up at the ceiling.
- I placed a 3" 90 deg elbo aprox 12" off the floor with the tower fan infront of it, allowing cooler air from under the stairs behind the flower room in. I then placed a 4" T above the HPS ontop of the ceiling allowing hot air to escape.
- I plan on connecting the Light exhaust to the room exhaust( "T") and placing the inline fan at the end, "Pulling" air from both and then pushing through a Carbon Scrubber I still have to make.
- Even without the inline fan in yet the temp at the pot level has averaged 80 deg. I have an old Weather gauge at the ceiling level and it averages 90+ and 60% hum. However, it is old and is coil style not mercury so I don't entierly trust it.View attachment 1368066View attachment 1368067View attachment 1368068View attachment 1368069
View attachment 1368070
View attachment 1368072
- 3' W x 5.5' D x 3.5'-7' H. (under a staircase)
- 4 bulb 4' T8/32w fixture, 2 cool white, 2 warm white. Hang from chains.
- 2- 2 bulb 4' T12/40w fixtures each with one cool white and one warm white. Mounted on the wall behind plants.
- one 12"or so, table top fan, should be oscilating but it was a hand me down and just clicks.
Room has remained at high 70s with about 55-60% hum, since construction @ the end of Oct.
There is no active ventalation and I believe that I should be fine given the small size of the room.
Flower Rm. Specs:
- 2.5' W x 5.5' D x 7' H
- 400w/ HPS/ 6" CoolTube.
- One med tower fan
- 4" inline bilge/galley fan-240 cfm.(It's for boats and only cost me $35.00 off Ebay with shipping)
- Current set up is missing the inline fan because it has not arrived yet. Based on the "heat rises" concept the cold air intake for the CoolTube is aprx. 18" off of the floor while the hot air exhaust runs to a 6"-4" reducer fitting up at the ceiling.
- I placed a 3" 90 deg elbo aprox 12" off the floor with the tower fan infront of it, allowing cooler air from under the stairs behind the flower room in. I then placed a 4" T above the HPS ontop of the ceiling allowing hot air to escape.
- I plan on connecting the Light exhaust to the room exhaust( "T") and placing the inline fan at the end, "Pulling" air from both and then pushing through a Carbon Scrubber I still have to make.
- Even without the inline fan in yet the temp at the pot level has averaged 80 deg. I have an old Weather gauge at the ceiling level and it averages 90+ and 60% hum. However, it is old and is coil style not mercury so I don't entierly trust it.View attachment 1368066View attachment 1368067View attachment 1368068View attachment 1368069