Search results

  1. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    what makes you think you will be able to walk in between the plants when it gets going? the density of the 32 site is way too compact. I've searched the internet far and wide and nowhere have I seen one even set up and running.
  2. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    lol you obviously grow shit weak ass dwc plants to not hit that size dude
  3. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    fucking 4 systems in there lol. you trolllin huh?
  4. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    I take it you will be growing one strain at a time from seed with no mom area?
  5. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    lets just break it down this way. each plant you grow in dwc is going to take up a 3x3 square space 6 of those on the 20 ft wall, and 12 down the 40 foot wall. you only got density for 2 systems IF you dont have room for anything else in there like walking. so how "professional" do you want to look?
  6. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    their shit is put together with duct clamps and rubber. LOL
  7. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    I can beat it with non bulk internet pricing. 100 bucks for 32 black 5 gallon buckets 174.72 for 64 -2 inch uni seals 60 bucks for 36- 6 inch net pots $161.50 EcoPlus Commercial Air 7 - 200 Watt Single Outlet 3566 GPH 30 dollars for 32 airstones on ebay (40mm disks) 25 dollars for 30 feet of 2...
  8. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    bucket made of snake oil resin
  9. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    its gravity controlled, it has no engineering to it. I can build a 32 site with EVEN FLOW in a day. period. uni seals are fool proof as long as you sand, I understand not wanting to do the work. but 2600 dollars for a days worth of work is horseshit. what are you doing? cast molding pvc pipes...
  10. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    32 site at $4,652.06 - $6,389.96 LOL. DIY bro. l 32 5 gallon buckets cost like 3 dollars each. you really gonna shell out 12 grand for 3 systems that you can build for 600 each? mmmmmhmmmm?
  11. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    I was confused on which side of the coil would be cooling lol. I see now. me bad lol
  12. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    do you even have any experience running dwc this big? because you seem like you are biting off more than you can chew. ive never soon anyone run dwc this big just soil. for a reason. the amount of water you will use is fucking crazy. I do trust you will have automatic PH adjusters that will be...
  13. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    why would you put a chiller around a wort chiller? just use one chiller? cooling water to cool water in another system is easily bypassed by just using one chiller per row. you are going to need the dedicated cool in each leg. this whole wort chiller thing seems like a fuckery of failure. for real.
  14. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    do you mean put a coil in a box freezer unit?
  15. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    I haven't worked with chiller coil before. But with all them gavitas I just want to say no lol.
  16. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    Those slucket style bottom feeding systems are interesting. Big pvc up top to drain back
  17. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    Not big enough lol. 1.5 inch pvc. As big as I wanted to go with uni seals on round 5 gallons.
  18. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    Higher the flow rate means roots from 3 plants down are in my bucket here. And that's the only bitch of Rdwc.
  19. Purpsmagurps

    4 32 site xl undercurrent systems in a 20X40 room

    I would just insulate pvc and run to each bucket up top, use one chiller per isle. You are going to have a bitch of a time keeping your shit from tangling and clogging. I have only a 4 site and as soon as my roots fill up I need to adjust my top fill and my water level changes with flow rate...