Yeah that's what i was finding after a little more research...that sucks cause i know Arizona will recognize california's 215 card...suppose i will have to find someone and do it the old fashioned way...funny because i know with contractors license Arizona wouldn't recognize my California one...
Yeah im sure i could get a card there was just having some wishful thinking that i wouldn't need to bother with all that jazz and just find somewhere to purchase meds from..Will be staying in a hotel for the duration of our project so not even sure if that would be a suitable address for them.
Just wondering if anyone knew of hand if California would furnish meds to an Arizona med card holder. Info online is inconclusive some say certain places will and some say they wont..I am heading there in march for a few months for work but really didnt want to bring that amount of meds with...
If they are bored thats all they need...just knock knock and I smell marijuana..and you can grow outside here in AZ it has to be surrounded by a 10' wall and some other shit but it is "legal"..
I am an electrical contractor out here in AZ I've been in the trade coming to the 20 year mark and have worked in many many states. There is not a state out there or a city that I am aware of that you don't have to pull a permit for a main service upgrade. Also the only way you can upgrade a...
Yes you can...typically most 3 phase systems are made up of 3 120v hots...there are exceptions and you need to make sure what type of system you have..you can have a high leg delta which is where you middle leg or b phase when measured from hot to neutral can either be 208v 240v etc...just make...
I'm not sure but if you are a convicted felon on parole or probation i believe your 4th amendment is considered waived...in which case they can search anything of yours house, car, boat, person etc without a warrant at anytime...
You are correct as long as all the loads are 220v...the only problem is someone might see that and think they can run for example (3) 1000w lights at 220 and then start plugging in 120v fans, pumps, small ac's etc thinking they had another 3000w of power to utilize which will then potentially...
This is kind of what of I was telling him to do..the only problem is that 30amp circuit can't handle 5000w...a 5000w load is equal to 41.6amps...typically a 30amp dryer is ran in 10 gauge wire...40amps is ran in 8guage and 50amps is ran in 6guage and so on..
Also a common misconception is that...
The color temp isn't ideal...thats a pretty expensive bulb..you can get 2 1000w hps with similar lumens and a better color temp for the price...and since your posting in the az section I hope your not purchasing from the guy that post bulbs all the time on craigslist...he works for one of the...
Fatty..I have been an electrician for 20 years now...your best bet for your needs is to install a 50a double pole breaker in your main panel(there is space above the 15amp single in your picture) and run 6 gauge wire to a new sub panel in your room...12 space 24 circuit sub panel would run you...