Recent content by mrmadcow

  1. M

    CSI Stickyicky's Locking Metal Grow Cabinet Build

    nice setup! to cut noise,have you considered getting rid of the intake fans & going passive?
  2. M

    WYE for 1000w air cooled hood and 400cfm exhaust

    just use a passive intake
  3. M

    Grow Tent is 104 Degrees Farenheit

    you found the answer to your problem. how hot is the room that holds the tent? you are just recirculating the heat.it needs to be vented outside or to another room. and as stated already,use the bigger fan to exhaust or a passive intake. if getting rid of the hot air in the room doesn't solve...
  4. M

    My setup

    at 18? yeah right. spoken like a child! did I strike a nerve? you want to be respected? earn it! that starts w/ respecting others. if grandma is supporting your ass, you should respect her wishes or man up & get your own place! I dont care if its weed or whatever, her house,her rules! only a...
  5. M

    New light scheme

    8 bulbs or 8 fixtures containing 16 bulbs? t5,t8 or t12 ? either way, I would put them all at 1 end and space the HPS lights toward the other end but 16 bulbs will draw over 500 watts so if you have the juice to power them,a 400 or 600 could be added as well. many swear that a MH added to HPS...
  6. M

    First Grow(closet)Room Schematic

    & yellow paint is also 70% flat white paint is 85% reflective. emergency blankets are mylar & are a buck or 2 if cost is that important why use foil?
  7. M

    Digilux HPS 600 watt Bulb! Need help before using

    all the above are correct. it is designed to work w/ a digital ballast at a higher frequency than a mag ballast puts out so it wont give full lumens or spectrum. it may "pop" after extended use but my guess is that is rare & would only happen after a few hundred hours but even a few days of use...
  8. M

    light screens that block light but let air pass?

    light wont bend but does reflect so a couple duct elbows paints black on the inside will do what you need
  9. M

    First Grow(closet)Room Schematic

    foil sucks - use flat white paint or mylar.
  10. M

    My setup

    maybe you should man up & get your own place instead of risking grandma's house. only a child or weasel would shit on someone like that! hopefully someday you will have children that shit all over you like you are doing to your grandma.
  11. M

    T5 lighting/electrical expert needed

    with an attitude like this,why would anyone help you?
  12. M

    Portable A/C & HPS Lights duct "y" to chimney

    Not a HVAC guy so I don't know your answer but I do know you have to be careful when using your chimney.when you start forcing air into the chimney w/ fans,you could cause air to flow out all the open ends of the chimney,not just out the top. you need to be sure the air doesn't force it's way...
  13. M

    Timers for 220 V (digital)

    I assume you are talking about a hot water heater timer,if so you could put more than 1 light on a timer. Electrically, it is better to have the lights kick on a few minutes apart because when a ballast 1st fires, it will draw 2-3 times more amps than it is listed at for a few miliseconds. -your...
  14. M

    How do i stop light from exiting my vent holes?

    light wont bend around corners,a small box w/ a couple bends will stop it from escaping. it does reflect so make the inside black
  15. M

    Building Material

    that may be true in Europe but in the US, they need a search warrant & besides, the heat coming from a personal grow won't be extreme enough to show.