  1. st3pch1ld

    Portable a/c+2400w of led+hps

    You lack to realize, that this is a portable AC. Read the whole post. I cool 4k aircooled with a 14k portable dual hose in the winter, and 2400w with the same in the summer, and its a struggle holding temps.
  2. st3pch1ld

    10 by 5 Tent Set up

    First time grower?
  3. st3pch1ld

    mini split inside???

    Gree and Freidrich are decent systems as well for about half the price. There compressors are noticeably louder though. Definitly be looking at the outside compressor sound ratings while shopping. If you have the money go for a Mitsu, you won't be disappointed.
  4. st3pch1ld

    mini split inside???

    Seal the lung room as much as possible. hahaha. I should set this pipe down too, f*ckin stoners. I run 2 rooms, 4kw each. Each split is 22500 btu. These ac's are way too big for my grow, but I purchased bigger so I could expand in the future.
  5. st3pch1ld

    mini split inside???

    I can cool 8k with 1 AC, although I do not run 8k per room. I run 4kw per flower room. If your only running 2.4kw I would suggest a 18k or 16k split. It's way too big for your grow, but you could possibly grow into it as well, & will run much less often.
  6. st3pch1ld

    mini split inside???

    Just remember, having a huge lung room may not be the best idea. The room SHOULD be 100% sealed, as your sucking air in & out. If you don't you will have either cooler air invading your grow space, or warm air from your compressor. I'd do something smaller maybe 6x6, or 8x8. I wouldn't go...
  7. st3pch1ld

    mini split inside???

    I do this, and have for some years now. The compressor will warm up your "lung"? room within a few minutes normally. Put an intake and exhaust 6" or 8" fan on a cooling stat, so once you hit 100-120 this turns on your exhaust & intake. As far as noise, I framed in a small area about 6x6 next to...
  8. st3pch1ld

    mini split inside???

    More than likely the manufacturer will tell you that it will not be covered under warranty, because it's installed in an environment it wasn't designed to be in.
  9. st3pch1ld

    mini split inside???

    I currently run 2x Mitsubishi 22,500k in a small sealed room, for each one of my 10x10 flower rooms, set to exhaust once the room hits 110 degrees. This has worked flawlessly the last year and a half. Year round.
  10. st3pch1ld

    Fan quit!! Help!

    There aren't any CAN fans with reset buttons.
  11. st3pch1ld

    RO system question

    I would highly suggest bypassing your Softener as your are adding more salts to your water. I would highly suggest running an RO based on your PPM readings being so high. Stealth RO Systems are good, but a bit pricey. Other RO's can be purchased for much cheaper.
  12. st3pch1ld

    Can't water plants

    I've always taken the stupid sprayer off the end of the wand, and used it without an end.
  13. st3pch1ld

    Heat Problems

    Lights need to be in a closed loop as stated above. Air from outside > fan > hoods > outside.
  14. st3pch1ld

    Heat Problems

    Your cooling your lights with the portable ac's cold air? Is this correct? Do you have an intake from outside at all?
  15. st3pch1ld

    Hey Riu 600w or 1000w

    Personally I use 1000w Galaxy Select-A-Watt.. Pretty useful when temps are running too hot.. Just dim it down to 600...