Indoor Growing 36k watts vertical around 30 gallon smart pots+scrog Pics.
in the The Grow Room
forums; 2 weeks left over at my other place. 8 plants with 1k down hangers around them.
The walls are scrogged ...
-
Marijuana Toker
Marijuana Toker
36k watts vertical around 30 gallon smart pots+scrog Pics.
2 weeks left over at my other place. 8 plants with 1k down hangers around them.
The walls are scrogged 15 lights on one wall.
Then I air vented another 15 hoods 3 feet apart. The rest is down hangers, GDP and mean green are the strains.
Dirt sucks you gotta veg too long.
Room runs 6 tons of A/C.
-Commercial
Menlo_mid_summer.jpgMenlo_mid_summer.jpg3-ton mini.jpgdigi.jpgDSC02032.jpgScrog.jpgstarting to wire.jpg
Things may come to those who wait, but only the things left by those who hustle.
-
i like this setup. care to share what your pulling per light?
-
wowzers!! Hope you got like .02/kwh
-
Marijuana Toker
Marijuana Toker
Pretty close to one per light. The scrog likes getting light under it from the verticals near it. Makes me want to put down hangers next to another scrog. 30 gallon smart pots make some big trees if you veg them out good. It surprised me.
Things may come to those who wait, but only the things left by those who hustle.
-
what temps are you able to run with 6tons of ac? are you using co2 in there? are you using a 4x4 pattern or one girl per 1k?
-
Marijuana Toker
Marijuana Toker

Originally Posted by
patrickkawi37
what temps are you able to run with 6tons of ac? are you using co2 in there? are you using a 4x4 pattern or one girl per 1k?
4x4 pattern on all but one vertical lit plant. 6 tons with a 8'' can fan for intake not the Max but the high output one.
No CO2. Temps stayed 72-74f.
Did you notice the hard plastic coated fencing I used to scrog with. You seal it together with screws and 2x4's cut to 4ft wide. The fence comes 4ft wide. Then use four turn buckles two on each sides. You can get it so rigid you could lay on it and it might lower a foot. Makes a nice canopy.
-Commercial
Things may come to those who wait, but only the things left by those who hustle.
-

Originally Posted by
comercial
4x4 pattern on all but one vertical lit plant. 6 tons with a 8'' can fan for intake not the Max but the high output one.
No CO2. Temps stayed 72-74f.
Did you notice the hard plastic coated fencing I used to scrog with. You seal it together with screws and 2x4's cut to 4ft wide. The fence comes 4ft wide. Then use four turn buckles two on each sides. You can get it so rigid you could lay on it and it might lower a foot. Makes a nice canopy.
-Commercial
thats badass. looks like some hard work and time put at it.
have you tried running co2 before in one of your shops?
-
nice
Posting Permissions
- You may not post new threads
- You may not post replies
- You may not post attachments
- You may not edit your posts
-
Forum Rules