Default 250 watt hps heat?
ok if anyone has something to help me out please dont hesitate to offer your thoughts if you have been there done that i really would like your help..im going to be running my 250 watt hps with 4x 2700k 23 watt cfl for full spectrum in flowering my question is im going with 2x 6" inline fans for exaust one to each upper side of box what type of intake should i run for best results?should i do a passive intake for this set up or should i run a couple of 4" fans bottom side to assist with the intake? my box is 2x3x3 1/2 depth width hight i have 2 x 6" circulating fans inside for air flow...any help is apreciated..thanks and peace pot prosperity
Reply With Quote
  #2    
Old 11-29-2009, 04:42 PM
alexonfire's Avatar
Ganja Smoker
Pot Head
alexonfire is offline
 
Join Date: Nov 2008
Location: Center of the Universe
Posts: 284
alexonfire is on a distinguished road
Points: 7,348, Level: 12 Points: 7,348, Level: 12 Points: 7,348, Level: 12
Activity: 6% Activity: 6% Activity: 6%
As long as you have a vent at the bottom to let in cold air, if you have a fan that is pushing air out then there will be a negative pressure in the box and suck air in. Its good enough with the 2 6" fans unless your temps are going above 30 degree Celsius or 86 Fahrenheit then you might want to add one for intake.
__________________
BLUEBERRY Grow Journal:
http://www.rollitup.org/grow-journal...oset-grow.html
Reply With Quote
  #3    
Old 11-29-2009, 05:27 PM
stinkbudd1's Avatar
420 TIME
Stoner
stinkbudd1 is offline
 
Join Date: Aug 2009
Location: the coast of cali
Posts: 685
stinkbudd1 will become famous soon enough
Points: 8,078, Level: 13 Points: 8,078, Level: 13 Points: 8,078, Level: 13
Activity: 10% Activity: 10% Activity: 10%
yeah thats what i tried with my current cfl grow and when i sealed my box the temps got way to high then i had 1x 4" 80cfm exaust fan at the top and 2x 1 1/2 " passive intake holes in the bottom...maybe the exaust and intake were not large enough thats why im looking for some kind of ratio intake to exaust.. thanks for your reply...ppp
Reply With Quote
  #4    
Old 11-30-2009, 09:15 PM
stinkbudd1's Avatar
420 TIME
Stoner
stinkbudd1 is offline
 
Join Date: Aug 2009
Location: the coast of cali
Posts: 685
stinkbudd1 will become famous soon enough
Points: 8,078, Level: 13 Points: 8,078, Level: 13 Points: 8,078, Level: 13
Activity: 10% Activity: 10% Activity: 10%
anymore help would really apreciate it from anyone..
Reply With Quote
  #5    
Old 11-30-2009, 09:26 PM
Marijuana Toker
Marijuana Toker
Fman is offline
 
Join Date: May 2008
Posts: 196
Fman is on a distinguished road
Points: 2,521, Level: 7 Points: 2,521, Level: 7 Points: 2,521, Level: 7
Activity: 0% Activity: 0% Activity: 0%
I am not sure if this helps.
Here’s how you can calculate the amount of ventilation you need. If for instance you wanted to keep you grow room temperature from getting any more than 5° warmer than the intake air temperature, and you were using 400 watts of power, you’d make the calculation below in blue. The chart is based on the following formula. It is a well-established heat transfer formula.


(3.2 × 400) ÷ 5 = 256

---------------------------Calculating the passive intake.-------------------------

The Home Ventilating Institute recommends one square foot of open air inlet per 300 CFM of ventilation fan capacity.


If you were going to use 256 CFM, you’d want 256/300 square feet of intake area, which is 122.88 square inches.

Here are some options for the intake area for a 256 CFM ventilation fan:

1 hole - 12.5 inches in diameter.
2 holes – 8.84 inches in diameter.
3 holes – 7.22 inches in diameter.
4 holes – 6.25 inches in diameter.
5 holes – 5.59 inches in diameter.
6 holes – 5.11 inches in diameter.


Here is how to calculate the hole sizes:

1. Take the total area in square inches needed, in this case 122.88 square inches, and divide by the number of holes you want.
2. Then divide by Pi (3.14).
3. Take the square root of that value.
4. Then multiply by 2.

The answer is the diameter that each hole would need to be to make up the total area needed for intake.

A large number of small holes will create more backpressure than one large hole of equivalent area. This would be negligible unless you’re using a huge number of holes or you’re using ducting to supply the air to each intake hole. If you’re just cutting them in a wall you should be fine using 8 or less holes without having to take into account the extra backpressure.
Reply With Quote
  #6    
Old 11-30-2009, 09:27 PM
Able To Roll A Joint
Able to roll a joint
Dradden is offline
 
Join Date: Oct 2009
Posts: 79
Dradden is on a distinguished road
Points: 921, Level: 4 Points: 921, Level: 4 Points: 921, Level: 4
Activity: 0% Activity: 0% Activity: 0%
What is the CFM on the 6 inch and proposed 4 inch? Air pressure is tricky when you decide to add intake fans. It has to be very close to balanced. For that size area depending on CFM of the 2 six inch fans a 12 inch passive intake should be fine.

Edit: FMan do you play L2?...sry but had to ask :P
Reply With Quote
  #7    
Old 11-30-2009, 09:54 PM
stinkbudd1's Avatar
420 TIME
Stoner
stinkbudd1 is offline
 
Join Date: Aug 2009
Location: the coast of cali
Posts: 685
stinkbudd1 will become famous soon enough
Points: 8,078, Level: 13 Points: 8,078, Level: 13 Points: 8,078, Level: 13
Activity: 10% Activity: 10% Activity: 10%
Quote:
Originally Posted by Fman View Post
I am not sure if this helps.
Here’s how you can calculate the amount of ventilation you need. If for instance you wanted to keep you grow room temperature from getting any more than 5° warmer than the intake air temperature, and you were using 400 watts of power, you’d make the calculation below in blue. The chart is based on the following formula. It is a well-established heat transfer formula.


(3.2 × 400) ÷ 5 = 256

---------------------------Calculating the passive intake.-------------------------

The Home Ventilating Institute recommends one square foot of open air inlet per 300 CFM of ventilation fan capacity.

If you were going to use 256 CFM, you’d want 256/300 square feet of intake area, which is 122.88 square inches.

Here are some options for the intake area for a 256 CFM ventilation fan:

1 hole - 12.5 inches in diameter.
2 holes – 8.84 inches in diameter.
3 holes – 7.22 inches in diameter.
4 holes – 6.25 inches in diameter.
5 holes – 5.59 inches in diameter.
6 holes – 5.11 inches in diameter.


Here is how to calculate the hole sizes:

1. Take the total area in square inches needed, in this case 122.88 square inches, and divide by the number of holes you want.
2. Then divide by Pi (3.14).
3. Take the square root of that value.
4. Then multiply by 2.

The answer is the diameter that each hole would need to be to make up the total area needed for intake.

A large number of small holes will create more backpressure than one large hole of equivalent area. This would be negligible unless you’re using a huge number of holes or you’re using ducting to supply the air to each intake hole. If you’re just cutting them in a wall you should be fine using 8 or less holes without having to take into account the extra backpressure.
hey man thanks thats what ive been looking for something solid im kind of technical almost anal about it when you start purchaceing high price beans lol thanks to you + rep my man...

Quote:
Originally Posted by Dradden View Post
What is the CFM on the 6 inch and proposed 4 inch? Air pressure is tricky when you decide to add intake fans. It has to be very close to balanced. For that size area depending on CFM of the 2 six inch fans a 12 inch passive intake should be fine.hey dradden they are 150 cfm rated each and the 4 inch intake is 80 cfm's rated so your saying of i run a passive intake and my two exaust are 320 cfm = 12"total my passive should be almost equal say 10" or so..? also ill be using one strictly for cooling the light and the other for cab exaust..

Edit: FMan do you play L2?...sry but had to ask :P
 

Tags
250, heat, hps, watt

Thread Tools
Display Modes

Thread

Thread Starter

Forum

Replies

Last Post

Another CFL vs HPS facts and heat temps. ez_growin General Marijuana Growing 33 01-05-2010 11:57 PM
CFL Tutorial Roseman CFL Growing 174 11-22-2009 04:22 PM
250 watt hps Grow (Random Headie seeds) Jcway5 Indoor Growing 5 11-04-2009 11:41 AM
250 watt digital HPS systems bunnyweed Indoor Growing 3 08-19-2009 08:08 AM
250 watt MH 8 veg 400watt hps flowering waiting2inhale Newbie Central 3 11-15-2007 03:06 PM

Posting Rules

You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Come Check out a new Poker Forum for the online poker community

All times are GMT -7. The time now is 07:56 AM.
Powered by vBulletin
Copyright © 2000-2009 Jelsoft Enterprises Limited.
Page generated in 0.23641 seconds with 11 queries

Content Relevant URLs by vBSEO 3.3.2