    Default Co2 controller for sealed room { help needed }

    I am setting up a sealed room,and need to get a co2 controller.
    I am on a budget and would like to spend less than 6oo.
    I am going to run ac and a humidifier if i need one.
    Do i just need a co2 cont or aa tempcontroll aswell?

    I will have 1 x 1o" exaust just incase of overheating
    I was looking into the sentinals but am open to all
    Thanks for reading,cheers
    Boycott kellogs,eat generic ricekrispies!

  2. #2
    Learning How To Roll Learning How To Roll
    Join Date
    Jan 2009

    Posts
    43

    Default

    Quote Originally Posted by headbandrocker View Post
    I am setting up a sealed room,and need to get a co2 controller.
    I am on a budget and would like to spend less than 6oo.
    I am going to run ac and a humidifier if i need one.
    Do i just need a co2 cont or aa tempcontroll aswell?

    I will have 1 x 1o" exaust just incase of overheating
    I was looking into the sentinals but am open to all
    Thanks for reading,cheers
    Honestly, if you're going for a sealed room, co2, and to also control heat and humidity, on a budget, I think you should wait.

    To get everything dialed in correctly (co2, heat especially), takes a decent amount of cash. Unless you live in cold climate , your biggest issue with sealed room is heat.

  3. #3
    Teaching How To Roll Mr. Ganja headbandrocker's Avatar
    Join Date
    May 2008

    Location
    Peru
    Posts
    1,210

    Default

    I was going to get a 24,ooobtu window a/c to run.
    What would you recomend i do then? Im interested in saving money but thought co2 was a big part of the cea /sealed rooms.I think im gona run my 1k bulbs with no hood vertically.Im shooting for 85 degrees w all 6 lights on and at 3ooobtu per 1k=18,ooo btu needed at most.If you canhelp me with a better layout heres a list of
    Gear i have:
    12" elecient fan
    8" vortex
    6 x 1kballasts
    7 x 8'' ac hoods
    ebb and flow bucket system

    Thanks for your help,cheers
    Boycott kellogs,eat generic ricekrispies!

  4. #4
    Learning How To Roll Learning How To Roll avgdude7's Avatar
    Join Date
    Feb 2009

    Posts
    33

    Default

    I know for a fact that with a little math a fella can just run c02 out the bottle, through the regulator/flowmeter, and solenoid valve set up with timers to reach your desired saturation levels. search co2 calculator, it'll give ya everything u need to know, I'm envious of a 2 ton window unit, I got a 1 ton yesterday 4 cheap at a garage sale. The absolute minimum u need for c02 equipment is regulator/flowmeter with a solenoid valve and either 1 or 2 timers, and obviously a bottle.
    I'll live my life without regard for social conformity and the status quo.

  5. #5
    Learning How To Roll Learning How To Roll faceoff13's Avatar
    Join Date
    Mar 2009

    Location
    My Bed Room
    Posts
    43

    Default

    good informatiom avgdude7
    Welcome to My' Marijuana page I'm a hobo, please dont dog me; I'm trying hard...

  6. #6
    Learning How To Roll Learning How To Roll tjizzle's Avatar
    Join Date
    May 2009

    Location
    Il
    Posts
    40

    Default

    hi I want to try the same thing .but i was going to try a swamp fan.it runs on the same princible as a fan blowing through a wet sheet.Southern poor mans ac.Its nothing more than a fan with a water pump .even with a dehumidifier running it could save thousands in a years time .Or if you run off gennys it allows more electricity for more lights.I use one to cool off my house last summer cause I didn't want my electric bill to go any higher .cooled it off fast.but not as cool as ac .I'll seal off my room as soon as I have the money for the co2 monitor ,regulator.

  7. #7
    Learning How To Roll Learning How To Roll avgdude7's Avatar
    Join Date
    Feb 2009

    Posts
    33

    Default

    thanks, faceoff13, and I hear ya tjizzle on waiting for the controller, I was kinda in the same boat then I started thinking about it, they want $1500 for a c02 controller where I live, but thats more for syncing the c02 release with in/out fans in a conventional set-up (not CGE/perfect room). So, armed with a little knowledge of gases, gas flow thru a given orifice and saturation levels one can figure out your flow time and flow volume required for your size of room and desired saturation level. Then I found this C02 calculator on here that did the same thing in 2 minutes..... I know my idas are kinda hillbilly but my $1500 could definetly go to better purchases, christ, I've heard of ppl growing without PH or TDS measuring devices....


    P.S. that C02 calculator is stickied on indoor growing !!!!
    Last edited by avgdude7; 05-31-2009 at 10:03 AM.
    I'll live my life without regard for social conformity and the status quo.

  8. #8
    Teaching How To Roll Mr. Ganja headbandrocker's Avatar
    Join Date
    May 2008

    Location
    Peru
    Posts
    1,210

    Default

    lol my first two rounds were w/o ph/ppm checking! lol

    Where i live the co2 controller i want is only 4 or 5 hundo...im interested cause of ease of use and for pest controll just pump ppms to 1o,oooppm for an hr and no mas bugs.
    I have seen the calc,and might go for it as my power bill this mo is $1487! thts not even with all lights on.
    To help lower my bill i will flower with 6/12! yes 6/12 not 12/12.
    A hydrofinned heatreducer/exchanger is way cheaper to run for sure but im gettin my ac at HD fer 5oo but im gona charge and pay it off after the cycle.
    Im leaning twards the sentinl controllers,anyone using them?
    Boycott kellogs,eat generic ricekrispies!

  9. #9
    Mr.Ganja Mr. Ganja BigBudBalls's Avatar
    Join Date
    Feb 2008

    Location
    on an Ozone Expedition
    Posts
    3,632

    Default

    be careful of a too big AC unit. If it cools the room down too fast, the humidity/moisture will condense in the room instead of the evaporation coil. This can create mold.
    The Temporary Relief Assistant Trailer Park Supervisor. Carmelisous Jornl :: ElecUsageCostsCalc (now with carbon footprint) :: FloroTubeCompendium ::

  10. #10
    Teaching How To Roll Mr. Ganja headbandrocker's Avatar
    Join Date
    May 2008

    Location
    Peru
    Posts
    1,210

    Default

    Im trying to keep it at 85,i could get this for 4oo out the door
    http://www.growlightexpress.com/envi...roller-84.html
    or should i get the temp/hum/co2 bundle controll?
    Boycott kellogs,eat generic ricekrispies!

Page 1 of 11 123 ... LastLast

Similar Threads

  1. wireing ??
    By Odis in forum General Marijuana Growing
    Replies: 20
    Last Post: 08-03-2010, 01:24 PM
  2. Replies: 828
    Last Post: 07-24-2009, 06:12 AM
  3. Grow Room Planning, Help Needed
    By GroKing in forum Grow Room Design & Setup
    Replies: 13
    Last Post: 04-21-2009, 06:54 PM
  4. Project Grow Room
    By Chronic_Productionz in forum Indoor Growing
    Replies: 29
    Last Post: 01-06-2007, 10:43 PM
  5. Project Grow Room
    By Chronic_Productionz in forum Indoor Growing
    Replies: 0
    Last Post: 01-02-2007, 12:43 PM

Tags for this Thread

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •