    164

    Default

    In my neck of the woods LEo aint a whole lot concerned about growers with cards. I know of One case where LEO's csme to my friends house because of a complaint, unrelated to his grow and discovered that he had about 200 more plants than he was allowed. All they did was reduce the number to his limit and told him to have a nice day. No charges of any kind to date.
    Keep in mind this is in the states so your milage may vary

  2. #1002
    Marijuana Toker Marijuana Toker curioushiker's Avatar
    Join Date
    Oct 2009

    Posts
    164

    Default

    Quote Originally Posted by wyteboi View Post
    i dont think YOU can upgrade to 200 with a 200 main , but u can go 125.
    The less resistance , the lower the bill .
    this is very hard to explain but here goes:

    IF u were to use every other breaker in the box , then u would be putting all your load on one phase of the power .... which puts a huge load on your neutral wire. so if one of your phases is only using 2 amps and the other one is using 40 amps then the load on the neutral should be 38 amps. which will make your bill alot higher then, say one phase is using 20 amps and the other phase is using 22 amps that means the load on your neutral is only 2 amps. thats alot less resistance which means a little less bill. (disclaimer: i am not a "master" i am just a residential electrician so i still have alot to learn , so im sorry if my info is hard to understand or if i am not 100% right )
    maybe roland/bigballs can help me here.....
    Makes sense to me. In fact perfect sense for some reason.
    But what I dont understand is how the 25 extra amps at the sub makes any difference.
    For example. My 100 amp sub has Eight spaces, Seven of which are used right now. One curcuit is used for Two small water pumps. The other Two 120v curcuits are for outlets, half the outlets to One the other half to the other curcuit. Then there are the Two 220 curcuits.
    If I am correct the feed wire is rated to 125 amps (#2 copper) so I guess I could upgrade if needed but I figured I would rather have my breakers be the week link versus the wire?
    Man if I let the stuff get away from me it can get real confusing.

  3. #1003
    Stranger Stranger ascaryblackguy's Avatar
    Join Date
    Nov 2009

    Posts
    13

    Default

    is it possible to splice a computer fan to run off ac power its an old school windows 95 fan 12v 0.35 a brushless fan it has 3 cords so im kinda confuzzled a bit but i wanna splice it so i can use it as a vent in my stealth grow box dresser so i need it to run at 0 sound is his possible ? o and could i splice it to a adapter that runs 12v 1.5 a with 100-240v input :S
    Last edited by ascaryblackguy; 11-13-2009 at 05:28 AM.

  4. #1004
    Able To Roll A Joint Able to roll a joint
    Join Date
    Apr 2009

    Location
    about 3' off the ground, near as I can tell
    Posts
    56

    Default RV battery for UPS ???

    Quote Originally Posted by haikubutthead View Post
    I use a UPS battery backup for my 396gph pumps in case of electrical outage. It is now time to replace the batteries. It take two small (motorcycle battery size) batteries, 12V, 7amp. Can I somehow use a big RV deep cycle battery instead? Longer life, etc.
    One RV battery is cheaper than replacing the two smaller batteries. Anyone?

  5. #1005
    Veteran Smoker Mr. Ganja wyteboi's Avatar
    Join Date
    Apr 2009

    Location
    uhh...uhhh..I think so ?
    Posts
    1,775

    Default

    Quote Originally Posted by haikubutthead View Post
    One RV battery is cheaper than replacing the two smaller batteries. Anyone?
    i am really not sure but i dont think its that easy.
    Quote Originally Posted by oakley1984 View Post
    i havent failed a 1000 times, ive successfully discovered a 1000 ways how to not make a clone
    Sometimes people get lost in the internet an forget about the real world.... soil

  6. #1006
    Veteran Smoker Mr. Ganja wyteboi's Avatar
    Join Date
    Apr 2009

    Location
    uhh...uhhh..I think so ?
    Posts
    1,775

    Default

    Quote Originally Posted by curioushiker View Post
    Makes sense to me. In fact perfect sense for some reason.
    But what I dont understand is how the 25 extra amps at the sub makes any difference.
    For example. My 100 amp sub has Eight spaces, Seven of which are used right now. One curcuit is used for Two small water pumps. The other Two 120v curcuits are for outlets, half the outlets to One the other half to the other curcuit. Then there are the Two 220 curcuits.
    If I am correct the feed wire is rated to 125 amps (#2 copper) so I guess I could upgrade if needed but I figured I would rather have my breakers be the week link versus the wire?
    Man if I let the stuff get away from me it can get real confusing.
    u do not need to do anything, u are fine the way u are. if i knew i was going to be running 80 CONSTANT then i would go with a 125 , but thats just me.... your setup is "safe" (as long as everything is hooked up right)
    Quote Originally Posted by oakley1984 View Post
    i havent failed a 1000 times, ive successfully discovered a 1000 ways how to not make a clone
    Sometimes people get lost in the internet an forget about the real world.... soil

  7. #1007
    Mr.Ganja Mr. Ganja BigBudBalls's Avatar
    Join Date
    Feb 2008

    Location
    on an Ozone Expedition
    Posts
    3,632

    Default

    not entirely true. newer digital meters can record usage trends.

    Quote Originally Posted by wyteboi View Post
    the only thing they can read is how much power u use every month not every "spike"
    the only time one worries about the power company is when u have had a very consistent small bill (for years) and then it jumps up to alot (lets say from 50 to 180)
    then they might call you and ask you if u know why ur bill is so high . (just to let u know that it is way above normal)
    now if your bill is 50 then 150 then 70 then 210 an so on, then they might tip the police that something aint right.
    Most of the time when someone gets busted from the power company then it is because they are trying to steal power or do somthing plain stupid. (one example of stupid would be : if they do call and ask u if u know why ur bill is higher then normal , then u say "i leave my lights on at night" or "yea i got 5 computers running" ....... thats just not enough to raise it so then they know ur hiding somthing.
    (i know i didnt really answer the question but thats my 1.5 cents on it
    The Temporary Relief Assistant Trailer Park Supervisor. Carmelisous Jornl :: ElecUsageCostsCalc (now with carbon footprint) :: FloroTubeCompendium ::

  8. #1008
    Marijuana Toker Marijuana Toker curioushiker's Avatar
    Join Date
    Oct 2009

    Posts
    164

    Default

    Quote Originally Posted by wyteboi View Post
    u do not need to do anything, u are fine the way u are. if i knew i was going to be running 80 CONSTANT then i would go with a 125 , but thats just me.... your setup is "safe" (as long as everything is hooked up right)
    I got ya. You were referring to overall load vs sub panel rating. Yeah, I know when I figured my amps I was very liberal in the numbers being that there are some variables, like the circulating fans that I wll run, how many ets etc.
    I know things always change. If I need to change my sub I can do that easy enough.
    Can you tell me what is the physical difference between a 100 and 125 amp sub panel? Are the lugs and buses bigger?

  9. #1009
    Able To Roll A Joint Able to roll a joint
    Join Date
    Jun 2009

    Location
    Canada
    Posts
    50

    Default

    I have tested and the red one going into my 100amp pony box is dead while the black is the usual 120.

    I am going to post some pics tomorrow so you can see.

    My system has:

    1. Meter with lead cap from utility company

    2. a big main breaker with two 100amp fuses inside (scary looking)

    then it runs to a few 30amp old school fuse boxes and my pony panel.

    Any thoughts on next steps?

    Quote Originally Posted by wyteboi View Post
    sorry it took so long , but u have "blew" one phase of your panel . If u were to test the main breaker , only one side is gonna be putting out 120 volts, the other side will be "dead" or not reading right.
    To fix we must have a tester (that reads how many volts) i need to know where exactly we "lost" the second phase?
    First with leather or rubber gloves , turn main breaker off and then back on ...... the movement might be enough to turn it back on, or the main breaker might just be bad.
    cause when one side of a 2 pole breaker "pops" then both sides should "pop".
    Is this 100 amp panel a sub ? (coming off another panel)... if so we want to check the breaker feeding your 100 and the big wires going to/from the 100. usally if u look close enough u will find the problem. now if this is your only panel in the house then the problem may be in the meter base outside ? come back when u have a tester.........
    (dont forget the big wires feeding your 100 amp panel are hot no matter if u shut off the 100 amp breaker)

  10. #1010
    Stranger Stranger
    Join Date
    Nov 2009

    Posts
    18

    Default 250w flood lights questions.

    Hi

    I have aquired 2x 250W HPS flood lights with asymmetrical mirrors and im wondering how best to utilize them.

    They came with MH bulbs so the first question is, can they take the HPS bulbs i intend to buy?

    On the Ballast, it says 250w, i assume that is the max the ballast can handle and trying to put a bigger bulb in would not work or damage the ballast.

    Since those lamps are quite heavy im wondering if it is all right to remove all electronics from the lamp and rewire the connection from ballast to bulb to increase lenght of wires and allow for cooltube setup.

    How can i tell if the ballast is 'Electronic' or the old type (whatever that is called).

    How can i tell if the ballast is HO (High Output) and so determine if a HO bulb would be an improvement.

    Thanks for the help, greatly appreciated.