Default Help with sub-panel

So I would like to set up a new grow in an outbuilding. Unfortunately, its not really going to be possible to run new wire to the site, the neighbors would likely find it suspicious. Currently there is an underground 12/2, 20 amp line going to the site. Is there any reason why I could retro-fit it to carry 240v to a sub-panel at the site? I'm not an electrician so please bear with me. Id like to run 2 1200 watt ballasts (4 600 watt) along with some fans and pumps. The total setup should stay under 40 amps. Would it be safe to rewire the line? Current code requires that a 240v wire have both a ground and a neutral but is this absolutely necessary, I know it was done with only three wires for many years? I intend to run it off of a main panel with a 40 amp breaker and have 4 15 amp breakers at the sub-panel. Assuming that all of the electrical junctions and wiring is done properly, I just want to know if my plan to use the current 12/2 is (relatively) safe?

I've included a little diagram of my plans, sorry I'm no schematician (probably not a word).
Order your seeds now
Attached Images
File Type: jpg directionstoburnunit.jpg (39.4 KB, 0 views)
Reply With Quote
  #2  
Old 04-29-2008, 10:18 PM
SeattlePot's Avatar
Marijuana Toker
Marijuana Toker
 
Join Date: Feb 2008
Posts: 104
Gallery:
SeattlePot is on a distinguished road
Points: 768, Level: 4 Points: 768, Level: 4 Points: 768, Level: 4
Activity: 0% Activity: 0% Activity: 0%
Default

bumpitty-bump-bump
Reply With Quote
  #3  
Old 04-30-2008, 12:37 AM
liquor2's Avatar
Stranger
Stranger
 
Join Date: Apr 2008
Posts: 15
Gallery:
liquor2 is on a distinguished road
Points: 270, Level: 2 Points: 270, Level: 2 Points: 270, Level: 2
Activity: 0% Activity: 0% Activity: 0%
Default

12/2 is not going to cut it. This is what I would do. I'd measure the distance from the panel to where your going to put the subpanel. I.E 50 feet, add 10 feet because you will need it. You are going to need a 8/3 wire for an 40 amp subpanel. If not you will pop breakers all day long. Start at the panel and disconnect the wires leading to the outhouse and duct tape the new 8/3 wire to the old wires, now go to the out house and and disonnect the out and get to the wires. Start pulling the wire until you get your new wires. Wire up your subpanel and the go back to your panel and wire that up. This is provided that your wire is ran in conduit under ground like it should be per N.E.C
Reply With Quote
  #4  
Old 05-02-2008, 09:43 AM
Stranger
Stranger
 
Join Date: Feb 2008
Posts: 13
Gallery:
riproor is on a distinguished road
Points: 404, Level: 3 Points: 404, Level: 3 Points: 404, Level: 3
Activity: 0% Activity: 0% Activity: 0%
Default

nope, go get some 6/3 uf direct burial, and run a 60amp 2 pole breaker from main panel out to the sub, , and if you are drawing 40 amps total, your main breaker feeding it must no exceed 80 percent of your FLA
Reply With Quote
  #5  
Old 05-02-2008, 07:54 PM
VictorVIcious's Avatar
Mr.Ganja
Mr. Ganja
 
Join Date: Sep 2006
Location: Northeastern USA
Posts: 4,876
Gallery:
VictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud of
Points: 14,303, Level: 17 Points: 14,303, Level: 17 Points: 14,303, Level: 17
Activity: 11% Activity: 11% Activity: 11%
Default

Quote:
Originally Posted by riproor View Post
nope, go get some 6/3 uf direct burial, and run a 60amp 2 pole breaker from main panel out to the sub, , and if you are drawing 40 amps total, your main breaker feeding it must no exceed 80 percent of your FLA
yep VV
Reply With Quote
  #6  
Old 05-13-2008, 06:39 AM
Stranger
Stranger
 
Join Date: May 2008
Location: miami
Posts: 3
Gallery:
tmacfl is on a distinguished road
Points: 211, Level: 2 Points: 211, Level: 2 Points: 211, Level: 2
Activity: 0% Activity: 0% Activity: 0%
Default

Anybody have any diagrams involving subpanel wired to a heavy duty timer with a stove cord?
Reply With Quote
  #7  
Old 05-13-2008, 04:50 PM
VictorVIcious's Avatar
Mr.Ganja
Mr. Ganja
 
Join Date: Sep 2006
Location: Northeastern USA
Posts: 4,876
Gallery:
VictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud ofVictorVIcious has much to be proud of
Points: 14,303, Level: 17 Points: 14,303, Level: 17 Points: 14,303, Level: 17
Activity: 11% Activity: 11% Activity: 11%
Default

Quote:
Originally Posted by tmacfl View Post
Anybody have any diagrams involving subpanel wired to a heavy duty timer with a stove cord?
A 'sub panel' doesn't need to be wired to a timer. You would run a circuit for the timer from the sub panel along with any other circuits you want. I'm not sure I understand your question, can you expand a little. VV
Reply With Quote
  #8  
Old 05-16-2008, 08:27 PM
blackcoupe01's Avatar
Stoner
Stoner
 
Join Date: May 2008
Location: Funky Town
Posts: 867
Gallery:
blackcoupe01 is a jewel in the roughblackcoupe01 is a jewel in the roughblackcoupe01 is a jewel in the rough
Points: 2,994, Level: 8 Points: 2,994, Level: 8 Points: 2,994, Level: 8
Activity: 0% Activity: 0% Activity: 0%
Default

That 12/2 is not even close to good enough. I believe 12-2 UF is rated at 25amps, not sure maybe 20A. You really need to up the wire size, 6awg or 8awg may do the trick, How far is your spot from the electrical panel. Would you be able to run a new wire from the panel to your spot. I'd try making friends with an electrician
Reply With Quote
Reply
Tags: , ,


Tags
amps, electricity, sub panel, subpanel

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
A power panel to keep electrics safe and neat Al B. Fuct Indoor Growing 39 09-03-2008 02:30 AM
Add Led light panel along w/ flourescents thaman420 CFL Growing 3 04-12-2008 08:51 PM
Control Panel Problems Cearid Support 21 02-24-2008 04:59 AM
LED light panel Kassidy Do It Yourself 25 01-07-2008 06:08 PM
Panel Seeks Records of Political Briefings at Agencies Dankdude Politics 4 05-01-2007 01:15 PM


Smoke Legal Buds

Come Check out a new Poker Forum for the online poker community

All times are GMT -7. The time now is 12:57 AM.


Powered by vBulletin® Version 3.7.2
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Content Relevant URLs by vBSEO 3.2.0
Page generated in 0.48654 seconds with 13 queries